Power unit for open sea conditions

High efficiency

High efficiency

Low energy consumption

Low energy consumption

Compact design

Compact design

Low noise level

Low noise level

Robust design

Robust design

Designed to comply with RoHS and REACH requirements

Designed to comply with RoHS and REACH requirements

Combined power unit FCA/AR consists of 400 Hz (5-250 kWt) converter and 28 В (100-1200 А)DC rectifier. Used as aircraft power source in open sea conditions.

Combined frequency converter can be produced in standard set as well as according to special customer requirements.

Designed on standard combined power unit with additional functions which provide more operable convenience in open sea working process:

  • electric charge grounding bolts
  • sealed cable input and connections
  • door locks
  • shock-absorbers

The equipment meets all the standards for extreme working conditions.
Output parameters: 
Rated output power, kVA 5-250
Rated output voltage phase/line, V 3×115/200
Output voltage frequency, Hz 400±0,001
Output voltage regulation accurancy, %  
— for the balanced load ± 0,5
-for 30% unbalanced load ± 0,5
Total harmonic content, %:  
— linear ≤ 2
— non-linear load ≤ 2
Voltage modulation, % ≤ 1
Phase symmetry, electrical degree:  
-for the balanced load 120±1
-for 30% unbalanced load 120±1
Range of load change, % 0-100
Crest factor 1,414±0,03
Permissible overload, %  
— during 600 sec. 125
— during 30 sec. 200
— during 10 sec. 250
— during 1 sec. 300
— during 1 sec. 300
   
Output parameters of rectifier AR:  
Rated output voltage, V 28,0
Pulsation coefficient of output volatge, % < 7,4
Rated output current, A 100-1200
Overall efficiency, % ≥ 92
Number of outputs 1 or 2
Overload current, for 2 seconds, A  2400
   
Output parameters:  
Supply main rated voltage, V 3 х 380/220
Supply main voltage permitted deviation, % ± 5
Supply nominal frequency, Hz 60/50
Supply main rated frequency, % ± 10
Line Current Distortion at nominal load THDI , % ≤ 7
Power factor at 100% load ≥ 0,97
Power consumption:  
— in standby mode with the switch off switch, W ≤ 50
— idling, кВт ≤ 1
Power interruption until 25 kw
Overall efficiency, not less, % ≥ 96
Starting current no, soft start
   
Additional data:  
Demensions (on the example of FCA-90/AR-600), W× H×D, mm 1000× 1400× 1000
Weight (on the example of FCA-90/AR-600), kg ≤660
Ingress protection IP55
Acoustic noise level at 1 m 55 вС
Maximum ambient temperature, ºС + 56°С
Minimal ambient temperature, ºС - 40°С
Relative humidity, % 0 — 95

Any questions?

Contact us, we will be happy to answer!

This email address is being protected from spambots. You need JavaScript enabled to view it.

Our clients

Наши клиенты
Наши клиенты
Наши клиенты
Наши клиенты
Наши клиенты
Наши клиенты

And many others